Error 80007


Description
Error 80007 can happen when you create a site in the "Logon server" or the "Licence Monitor" console.

Cause
This error occurs as a result of a communication problem between the ENI Mediaplus Logon server service and the Editions ENI licence server.
The ENI Mediaplus Logon service is started but is not in the expected state. This anomaly can happen if the "Local System" account or another user account without a password is associated with the ENI Médiaplus Logon server service.

Solution
Associate with the ENI Médiaplus Logon server service, a user account with the following characteristics:
   - a password,
   - the right to start a service
   - the right to access the Internet.
Restart the service and reconfigure the site in the "Logon server" or the "Licence Monitor" console.